The Force10 Networks C-Series are resilient chassis-based switches that deliver reliability, network control and scalability. The C-Series is designed to support mission critical applications with very low latency across converged networks. Comprehensive management capabilities make the C-Series a cost-effective and flexible deployment option.
Key Applications
- Low cost 100/1000 Mbps server aggregation for small- to medium-sized data centers (100s to 1,000s of servers)
- Cost-effective LAN core switch for small- and medium-campuses (100s to 1,000s of PCs)
- High density GbE aggregation for distribution into a multiple Gbps or 10 GbE backbone
- Cost-effective PoE-enabled 10/100/1000Base-T wiring closet aggregation of VoIP phones, wireless access points, video cameras or other IEEE 802.3af-compliant devices
Key Features
The Force10 C-Series is designed to provide inherent reliability, network control, and scalability for high performance Ethernet environments.
- Up to 384 line-rate 10/100/1000Base-T ports with full 15.4 W Class 3 PoE support in a 13-RU chassis
- Up to 64 line-rate 10 GbE ports with pluggable XFP modules
- Suite of security, access control and wiring closet edge features for enterprise networks
- VirtualView real-time network and application traffic monitoring for virtualized data centers
- PowerSmart intelligent power management features provide automatic sensing, provisioning and management of PoE power
- Full complement of standards-based Layer 2, IPv4 and IPv6 features for unicast and multicast applications
- 5 microsecond switching latency under full load for 64 byte frames
- Switch fabric capacity of up to 1.536 Tbps and up to 952 Mpps L2/L3 packet forwarding capacity
- High availability architecture
- 1+1 Route Processor Module (RPM) design
- Continuous runtime data plane monitoring and advanced in-service CLI diagnostic functions
- Power supply redundancy with load sharing power bus enabling uninterrupted VoIP calls during a power supply failure
C-Series Product Matrix
|
C300 |
C150 |
|
| Switch Fabric Capacity | 1.536 Tbps | 768 Gbps |
| Full-Mesh Forwarding Capacity | 952 Mpps | 476 Mpps |
| I/O Line Card Slots | 8 | 4 |
| Line-rate 10/100/1000 Base-T with Class 3 IEEE 802.3af PoE |
384 Ports at 15.4W | 192 Ports at 15.4W |
| Line-rate 100Base-FX or GbE SFP |
384 | 192 |
| Line-rate 10 GbE XFP | 64 | 32 |
| Chassis Size | 13 Rack Units 3 Units/19" Rack |
9 Rack Units 4 Units/19" Rack |
| Hardware Redundancy | Power, Route Processor, Switch Fabric, Passive Copper Backplane | |
| Operating System | Fully Modular | |
Chassis
C300- 8 line card slots
- 2 Route processor module with integrated switch fabric slots
- 8 Power supply module slots and 1 fan tray slot
- Size: 13 RU, 22.7 h x 17.4 w x 14.4" d (57.66 h x 44.2 w x 37.58 cm d)
- Weight with factory-installed components: 55 lbs (24.95 kg)
- Weight fully loaded: 152.27 lbs (69.07 kg)
- ISO 7779 A-weighted sound pressure level: 73.8 dBA at 73.4°F (23°C)
- AC power
- Nominal input voltage: 100–240 VAC 50/60 Hz
- Maximum thermal output:
- 4,978 BTU/h (1,498 W) at 100/120 VAC
- 4,864 BTU/h (1,459 W) at 200/220 VAC
- 14 A at 100 VAC
- 12 A at 120 VAC
- 7 A at 200 VAC
- 6 A at 240 VAC
- 8.7 KVA at 100/120 VAC
- 8.5 KVA at 200/240 VAC
- 8,675 W at 100/120 VAC
- 8,476 W at 200/240 VAC
- Nominal input voltage: –44 to –55 VDC
- Maximum thermal output: 4,231 BTU/h (1,240 W)
- Maximum current draw per DC PEM: 32 A
- Maximum power consumption: 1,460 W
- 4 line card slots
- 2 Route processor module with integrated switch fabric slots
- 6 Power supply module slots and 1 fan tray slot
- Size: 9 RU, 15.7 h x 17.5 w x 15.3" d (39.88 h x 44.45 w x 38.86 cm d)
- Weight with factory-installed components: 38 lbs (17.24 kg)
- Weight fully loaded: 86.63 lbs (39.29 kg)
- ISO 7779 A-weighted sound pressure level: 69.3 dBA at 73.4°F (23°C)
- AC Power
- Nominal input voltage: 100–240 VAC 50/60 Hz
- Maximum thermal output:
- 2,891 BTU/h (862 W) at 100/120 VAC
- 2,824 BTU/h (840 W) at 200/220 VAC
- Maximum input current per module:
- 14 A at 100 VAC
- 12 A at 120 VAC
- 7 A at 200 VAC
- 6 A at 240 VAC
- Maximum system power input:
- 4.5 KVA at 100/120 VAC
- 4.4 KVA at 200/240 VAC
- Maximum power consumption:
- 4,420 W at 100/120 VAC
- 4,319 W at 200/240 VAC
- Nominal input voltage: –44 to –55 VDC
- Maximum thermal output: 2,457 BTU/h (720 W)
- Maximum current draw per DC PEM: 32 A
- Maximum power consumption: 800 W
- 19" front rack mountable
- Maximum operating specifications:
- Temperature: 32° to 104°F
(0° to 40°C) - Altitude: no performance degradation to 10,000 feet (3,048 meters)
- Relative humidity: 5 to 85% (RH), non-condensing
- Temperature: 32° to 104°F
- Maximum non-operating specifications:
- Temperature: -40° to 158°F
(-40° to 70°C) - Maximum altitude: 15,000 feet (4,572 meters)
- Relative humidity: 5 to 95% (RH), non-condensing
- Temperature: -40° to 158°F
Redundancy/Availability
- 1+1 redundant Switch Fabric & Route Processor Modules (RPM)
- C300:
- 2+1 redundant system AC Power Supply Modules
- 1+1 redundant system DC Power Entry Modules
- 4+1 redundant PoE Power Supply Modules supporting up to
384 PoE ports at 15.4 W with deterministic failure mode
- C150:
- 1+1 redundant system AC Power Supply Modules
- 1+1 redundant system DC Power Entry Modules
- 2+2 redundant PoE Power Supply Modules supporting up to
192 PoE ports at 15.4 W with deterministic failure mode
- Online insertion and removal of all components
- Environmental self-monitoring
- MAC addresses:
- C150: 256K
- C300: 512K
- IPv4 routes: 12K
- IPv6 routes: 6K
- Switching fabric capacity:
- C150: 768 Gbps (476 Mpps)
- C300: 1,536 Tbps (952 Mpps)
- Link aggregation: 8 links per group, 128 groups per chassis
- Queues per port: 4 queues
- VLANs: 1024 VLANs with 4096 tag value support
- Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
- Line-rate Layer 3 routing: IPv4 and IPv6
- LAG load balancing: based on Layer 2, IPv4 or IPv6 headers
- Switching latency: <5 µs for 64 byte frames
IEEE Compliance
- 802.1AB LLDP
- 802.1D Bridging, STP
- 802.1p L2 Prioritization
- 802.1Q VLAN Tagging, Double VLAN Tagging, GVRP
- 802.1s MSTP
- 802.1w RSTP
- 802.1X Network Access Control
- 802.3ab Gigabit Ethernet (1000BASE-T)
- 802.3ac Frame Extensions for VLAN Tagging
- 802.3ad Link Aggregation with LACP
- 802.3ae 10 Gigabit Ethernet (10GBASE-X)
- 802.3af Power over Ethernet
- 802.3ak 10 Gigabit Ethernet (10GBASE-CX4)
- 802.3i Ethernet (10BASE-T)
- 802.3u Fast Ethernet
(100BASE-FX, 100BASE-TX) - 802.3x Flow Control
- 802.3z Gigabit Ethernet (1000BASE-X)
- ANSI/TIA-1057 LLDP-MED
- Force10 FRRP (Force10 Redundant Ring Protocol)
- Force10 PVST+
- MTU 9,252 bytes
RFC and I-D Compliance
General Internet Protocols- 768 UDP
- 793 TCP
- 854 Telnet
- 959 FTP
- 1321 MD5
- 1350 TFTP
- 2474 Differentiated Services
- 3164 Syslog
- draft-ietf-bfd-base-03 BFD
- 791 IPv4
- 792 ICMP
- 826 ARP
- 1027 Proxy ARP
- 1035 DNS (client)
- 1042 Ethernet Transmission
- 1191 Path MTU Discovery
- 1305 NTPv3
- 1519 CIDR
- 1542 BOOTP (relay)
- 1812 Routers
- 1858 IP Fragment Filtering
- 2131 DHCP (server and relay)
- 2338 VRRP
- 3021 31-bit Prefixes
- 3046 DHCP Option 82
- 3069 Private VLAN
- 3128 Tiny Fragment Attack Protection
- 1981 Path MTU Discovery (partial)
- 2460 IPv6
- 2461 Neighbor Discovery (partial)
- 2462 Stateless Address Autoconfiguration (partial)
- 2463 ICMPv6
- 2464 Ethernet Transmission
- 2675 Jumbograms
- 3587 Global Unicast Address Format
- 4291 Addressing
- 1058 RIPv1
- 2453 RIPv2
- 1587 NSSA
- 2154 MD5
- 2328 OSPFv2
- 2370 Opaque LSA
- 2740 OSPFv3
- 3623 Graceful Restart
- 4222 Prioritization and Congestion Avoidance
- 1997 Communities
- 2385 MD5
- 2439 Route Flap Damping
- 2545 Multiprotocol Extensions for IPv6
- 2796 Route Reflection
- 2842 Capabilities
- 2858 Multiprotocol Extensions
- 2918 Route Refresh
- 3065 Confederations
- 4360 Extended Communities
- 4893 4-byte ASN
- 5396 4-byte ASN Representation
- draft-ietf-idr-bgp4-20 BGPv4
- draft-ietf-idr-restart-06 Graceful Restart
- 1112 IGMPv1
- 2236 IGMPv2
- 3376 IGMPv3
- 3569 SSM for IPv4
- 4541 IGMPv1/v2 Snooping
- draft-ietf-pim-sm-v2-new-05 PIM-SM for IPv4
- 1155 SMIv1
- 1156 Internet MIB
- 1157 SNMPv1
- 1212 Concise MIB Definitions
- 1215 SNMP Traps
- 1493 Bridges MIB
- 1850 OSPFv2 MIB
- 1901 Community-based SNMPv2
- 2011 IP MIB
- 2012 TCP MIB
- 2013 UDP MIB
- 2024 DLSw MIB
- 2096 IP Forwarding Table MIB
- 2570 SNMPv3
- 2571 Management Frameworks
- 2572 Message Processing and
Dispatching - 2574 SNMPv3 USM
- 2575 SNMPv3 VACM
- 2576 Coexistence Between SNMPv1/v2/v3
- 2578 SMIv2
- 2579 Textual Conventions for SMIv2
- 2580 Conformance Statements for SMIv2
- 2618 RADIUS Authentication MIB
- 2665 Ethernet-like Interfaces MIB
- 2674 Extended Bridge MIB
- 2787 VRRP MIB
- 2819 RMON MIB (groups 1, 2, 3, 9)
- 2863 Interfaces MIB
- 2865 RADIUS
- 3273 RMON High Capacity MIB
- 3376 IGMPv3
- 3416 SNMPv2
- 3418 SNMP MIB
- 3434 RMON High Capacity Alarm MIB
- 3580 802.1X with RADIUS
- 5060 PIM MIB
- ANSI/TIA-1057 LLDP-MED MIB
- draft-grant-tacacs-02 TACACS+
- draft-ietf-idr-bgp4-mib-06 BGP MIBv1
- IEEE 802.1AB LLDP MIB, LLDP DOT1 MIB, LLDP DOT3 MIB
- ruzin-mstp-mib-02 MSTP MIB (traps)
- sFlow.org sFlowv5
- sFlow.org sFlowv5 MIB
(version 1.3) - FORCE10-BGP4-V2-MIB
- FORCE10-CS-CHASSIS-MIB
- FORCE10-IF-EXTENSION-MIB
- FORCE10-LINKAGG-MIB
- FORCE10-COPY-CONFIG-MIB
- FORCE10-MON-MIB
- FORCE10-PRODUCTS-MIB
- FORCE10-SMI
- FORCE10-SYSTEM-COMPONENT-MIB
- FORCE10-TC-MIB
- FORCE10-TRAP-ALARM-MIB
Regulatory Compliance
Safety- UL/CSA 60950-1, 1st Edition
- EN 60950-1, 1st Edition
- IEC 60950-1, 1st Edition Including all National Deviations and Group Differences
- EN 60825-1 Safety of Laser Products Part 1: Equipment Classification Requirements and User's Guide
- EN 60825-2 Safety of Laser Products Part 2: Safety of Optical Fibre Communication Systems
- FDA Regulation 21 CFR 1040.10 and 1040.11
- Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A
- Canada: ICES-003, Issue-4, Class A
- Europe: EN 55022: 2006 (CISPR 22: 2006), Class A
- Japan: VCCI V3/2007.04 Class A
- USA: FCC CFR 47 Part 15, Subpart B, Class A
- EN 300 386 V1.3.3: 2005 EMC for Network Equipment
- EN 55024: 1998 + A1: 2001 + A2: 2003
- EN 61000-3-2: Harmonic Current Emissions
- EN 61000-3-3:Voltage Fluctuations and Flicker
- EN 61000-4-2: ESD
- EN 61000-4-3: Radiated Immunity
- EN 61000-4-4: EFT
- EN 61000-4-5: Surge
- EN 61000-4-6: Low Frequency Conducted Immunity
All C-Series components are EU RoHS compliant.
Power and Thermal Specifications
| Order Number | Description | Power Draw (W) | Thermal Output (BTU/h) |
| CH-C150 | C150 4-slot chassis with backplane | 0 | 0 |
| CH-C300 | C300 8-slot chassis with backplane | 0 | 0 |
| CC-C150-FAN | C150 fan subsystem | 50 | 0 |
| CC-C150-FAN2 | C150 enhanced fan subsystem | 80 | 0 |
| CC-C300-FAN | C300 fan subsystem | 85 | 0 |
| CC-C300-FAN2 | C300 enhanced fan subsystem | 220 | 0 |
| LC-CB-RPM | Switch Fabric and Route Processor Module (series CB) | 100 | 341 |
| LC-CB-10GE-4P | 4-port 10 Gigabit Ethernet line card (series CB) | 100 | 341 |
| LC-CB-10GE-8P | 8-port 10 Gigabit Ethernet line card (series CB) | 120 | 409 |
| LC-CB-1GE-48P | 48-port Gigabit Ethernet line card (series CB) | 130 | 444 |
| LC-CB-GE-48T | 48-port 10/100/1000Base-T line card with RJ45 interfaces (series CB) | 100 | 341 |
| LC-CB-GE-48V | 48-port 10/100/1000Base-T line card with RJ45 interfaces and PoE (series CB) | 100 | 341 |
| LC-CB-10G-1G-36T | FlexMedia line card with 36 10/100/1000Base-T RJ45 interfaces, eight GbE interfaces and two 10 GbE interfaces (series CB) | 120 | 409 |
| LC-CB-10G-1G-36V | FlexMedia line card with 36 10/100/1000Base-T RJ45 interfaces with PoE, eight GbE interfaces, and two 10 GbE interfaces (series CB) | 120 | 409 |
Power Cord Specifications
The following power cords are used by the C150 and C300 with the CC-C-1200W-AC PSM (Power Supply Module).
All power cords have a straight C13 connector, and are 8' (2.44 m) long. The CC-C-1200W-AC PSM has a C14 power inlet.
| Order Number | Country | Plug | Rating | Approval |
|
CB-C-AC-12-CHN
|
China
|
GB 2099
|
250 VAC, 10 A
|
CCEE
|
|
CB-C-AC-12-EU
|
EU (not for UK or Switzerland)
|
CEE 7/7
|
250 VAC, 10 A
|
VDE
|
|
CB-C-AC-12-IND
|
India
|
BS 546
|
250 VAC, 10 A
|
SABS
|
|
CB-C-AC-12-JPN
|
Japan
|
JIS 8303
|
125 VAC, 15 A
|
UL
|
|
CB-C-AC-12-SWZ
|
Switzerland
|
SEV 1011
|
250 VAC, 10 A
|
SEV
|
|
CB-C-AC-12-UK
|
UK
|
BS 1363
|
250 VAC, 10 A
|
BSI
|
|
CB-C-AC-12-US
|
North America
|
NEMA 5-15P
|
125 VAC, 15 A
|
UL
|
|
CB-C-AC-12-US220
|
North America (220 V)
|
NEMA 6-15P
|
250 VAC, 10 A
|
UL
|